Eintrag weiter verarbeiten
Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes
Gespeichert in:
Zeitschriftentitel: | Open Engineering |
---|---|
Personen und Körperschaften: | , , |
In: | Open Engineering, 5, 2014, 1 |
Format: | E-Article |
Sprache: | Unbestimmt |
veröffentlicht: |
Walter de Gruyter GmbH
|
Schlagwörter: |
author_facet |
Changcharoen, W. Somravysin, P. Eiamsa-ard, S. Changcharoen, W. Somravysin, P. Eiamsa-ard, S. |
---|---|
author |
Changcharoen, W. Somravysin, P. Eiamsa-ard, S. |
spellingShingle |
Changcharoen, W. Somravysin, P. Eiamsa-ard, S. Open Engineering Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes Electrical and Electronic Engineering Mechanical Engineering Aerospace Engineering General Materials Science Civil and Structural Engineering Environmental Engineering |
author_sort |
changcharoen, w. |
spelling |
Changcharoen, W. Somravysin, P. Eiamsa-ard, S. 2391-5439 Walter de Gruyter GmbH Electrical and Electronic Engineering Mechanical Engineering Aerospace Engineering General Materials Science Civil and Structural Engineering Environmental Engineering http://dx.doi.org/10.1515/eng-2015-0009 <jats:title>Abstract</jats:title><jats:p>This article presents an experimental analysis of the turbulent flow of water in a heat exchanger tube fitted with peripherally-cut dual twisted tapes (PDTs) under a constant wall heat-flux condition. The peripherallycut dual twisted tapes with different cutting pitch ratios (l/y = 0.5, 0.75 and 1.0) were tested for Reynolds numbers in the range of 5400 to 14,000. The experimental results showed thatNusselt number and friction factor of the tubes fitted with PDTswere considerably higher than those of the plain tube and those of the tubes with single twisted tape (ST) and dual twisted tapes (DTs). It was found that PDTs with l/y = 0.5, 0.75 and 1.0 gave higher heat transfer rate than the typical DTs, with average Nusselt numbers greater by 12.1%, 7.8% and 3.8%, respectively. For the range investigated, PDTs with the smallest l/y ratio offered the highest thermal performance factor of 1.14.</jats:p> Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes Open Engineering |
doi_str_mv |
10.1515/eng-2015-0009 |
facet_avail |
Online Free |
finc_class_facet |
Biologie Technik Mathematik Physik Geographie |
format |
ElectronicArticle |
fullrecord |
blob:ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTUxNS9lbmctMjAxNS0wMDA5 |
id |
ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTUxNS9lbmctMjAxNS0wMDA5 |
institution |
DE-Pl11 DE-Rs1 DE-14 DE-105 DE-Ch1 DE-L229 DE-D275 DE-Bn3 DE-Brt1 DE-Zwi2 DE-D161 DE-Zi4 DE-Gla1 DE-15 |
imprint |
Walter de Gruyter GmbH, 2014 |
imprint_str_mv |
Walter de Gruyter GmbH, 2014 |
issn |
2391-5439 |
issn_str_mv |
2391-5439 |
language |
Undetermined |
mega_collection |
Walter de Gruyter GmbH (CrossRef) |
match_str |
changcharoen2014thermalandfluidflowcharacteristicsinatubeequippedwithperipherallycutdualtwistedtapes |
publishDateSort |
2014 |
publisher |
Walter de Gruyter GmbH |
recordtype |
ai |
record_format |
ai |
series |
Open Engineering |
source_id |
49 |
title |
Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_unstemmed |
Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_full |
Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_fullStr |
Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_full_unstemmed |
Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_short |
Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_sort |
thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
topic |
Electrical and Electronic Engineering Mechanical Engineering Aerospace Engineering General Materials Science Civil and Structural Engineering Environmental Engineering |
url |
http://dx.doi.org/10.1515/eng-2015-0009 |
publishDate |
2014 |
physical |
|
description |
<jats:title>Abstract</jats:title><jats:p>This article presents an experimental analysis of the turbulent flow of water in a heat exchanger tube fitted with peripherally-cut dual twisted tapes (PDTs) under a constant wall heat-flux condition. The peripherallycut dual twisted tapes with different cutting pitch ratios (l/y = 0.5, 0.75 and 1.0) were tested for Reynolds numbers in the range of 5400 to 14,000. The experimental results showed thatNusselt number and friction factor of the tubes fitted with PDTswere considerably higher than those of the plain tube and those of the tubes with single twisted tape (ST) and dual twisted tapes (DTs). It was found that PDTs with l/y = 0.5, 0.75 and 1.0 gave higher heat transfer rate than the typical DTs, with average Nusselt numbers greater by 12.1%, 7.8% and 3.8%, respectively. For the range investigated, PDTs with the smallest l/y ratio offered the highest thermal performance factor of 1.14.</jats:p> |
container_issue |
1 |
container_start_page |
0 |
container_title |
Open Engineering |
container_volume |
5 |
format_de105 |
Article, E-Article |
format_de14 |
Article, E-Article |
format_de15 |
Article, E-Article |
format_de520 |
Article, E-Article |
format_de540 |
Article, E-Article |
format_dech1 |
Article, E-Article |
format_ded117 |
Article, E-Article |
format_degla1 |
E-Article |
format_del152 |
Buch |
format_del189 |
Article, E-Article |
format_dezi4 |
Article |
format_dezwi2 |
Article, E-Article |
format_finc |
Article, E-Article |
format_nrw |
Article, E-Article |
_version_ |
1792328430240399361 |
geogr_code |
not assigned |
last_indexed |
2024-03-01T12:53:09.04Z |
geogr_code_person |
not assigned |
openURL |
url_ver=Z39.88-2004&ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fvufind.svn.sourceforge.net%3Agenerator&rft.title=Thermal+and+fluid+flow+characteristics+in+a+tube+equipped+with+peripherally-cut+dual+twisted+tapes&rft.date=2014-01-07&genre=article&issn=2391-5439&volume=5&issue=1&jtitle=Open+Engineering&atitle=Thermal+and+fluid+flow+characteristics+in+a+tube+equipped+with+peripherally-cut+dual+twisted+tapes&aulast=Eiamsa-ard&aufirst=S.&rft_id=info%3Adoi%2F10.1515%2Feng-2015-0009&rft.language%5B0%5D=und |
SOLR | |
_version_ | 1792328430240399361 |
author | Changcharoen, W., Somravysin, P., Eiamsa-ard, S. |
author_facet | Changcharoen, W., Somravysin, P., Eiamsa-ard, S., Changcharoen, W., Somravysin, P., Eiamsa-ard, S. |
author_sort | changcharoen, w. |
container_issue | 1 |
container_start_page | 0 |
container_title | Open Engineering |
container_volume | 5 |
description | <jats:title>Abstract</jats:title><jats:p>This article presents an experimental analysis of the turbulent flow of water in a heat exchanger tube fitted with peripherally-cut dual twisted tapes (PDTs) under a constant wall heat-flux condition. The peripherallycut dual twisted tapes with different cutting pitch ratios (l/y = 0.5, 0.75 and 1.0) were tested for Reynolds numbers in the range of 5400 to 14,000. The experimental results showed thatNusselt number and friction factor of the tubes fitted with PDTswere considerably higher than those of the plain tube and those of the tubes with single twisted tape (ST) and dual twisted tapes (DTs). It was found that PDTs with l/y = 0.5, 0.75 and 1.0 gave higher heat transfer rate than the typical DTs, with average Nusselt numbers greater by 12.1%, 7.8% and 3.8%, respectively. For the range investigated, PDTs with the smallest l/y ratio offered the highest thermal performance factor of 1.14.</jats:p> |
doi_str_mv | 10.1515/eng-2015-0009 |
facet_avail | Online, Free |
finc_class_facet | Biologie, Technik, Mathematik, Physik, Geographie |
format | ElectronicArticle |
format_de105 | Article, E-Article |
format_de14 | Article, E-Article |
format_de15 | Article, E-Article |
format_de520 | Article, E-Article |
format_de540 | Article, E-Article |
format_dech1 | Article, E-Article |
format_ded117 | Article, E-Article |
format_degla1 | E-Article |
format_del152 | Buch |
format_del189 | Article, E-Article |
format_dezi4 | Article |
format_dezwi2 | Article, E-Article |
format_finc | Article, E-Article |
format_nrw | Article, E-Article |
geogr_code | not assigned |
geogr_code_person | not assigned |
id | ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTUxNS9lbmctMjAxNS0wMDA5 |
imprint | Walter de Gruyter GmbH, 2014 |
imprint_str_mv | Walter de Gruyter GmbH, 2014 |
institution | DE-Pl11, DE-Rs1, DE-14, DE-105, DE-Ch1, DE-L229, DE-D275, DE-Bn3, DE-Brt1, DE-Zwi2, DE-D161, DE-Zi4, DE-Gla1, DE-15 |
issn | 2391-5439 |
issn_str_mv | 2391-5439 |
language | Undetermined |
last_indexed | 2024-03-01T12:53:09.04Z |
match_str | changcharoen2014thermalandfluidflowcharacteristicsinatubeequippedwithperipherallycutdualtwistedtapes |
mega_collection | Walter de Gruyter GmbH (CrossRef) |
physical | |
publishDate | 2014 |
publishDateSort | 2014 |
publisher | Walter de Gruyter GmbH |
record_format | ai |
recordtype | ai |
series | Open Engineering |
source_id | 49 |
spelling | Changcharoen, W. Somravysin, P. Eiamsa-ard, S. 2391-5439 Walter de Gruyter GmbH Electrical and Electronic Engineering Mechanical Engineering Aerospace Engineering General Materials Science Civil and Structural Engineering Environmental Engineering http://dx.doi.org/10.1515/eng-2015-0009 <jats:title>Abstract</jats:title><jats:p>This article presents an experimental analysis of the turbulent flow of water in a heat exchanger tube fitted with peripherally-cut dual twisted tapes (PDTs) under a constant wall heat-flux condition. The peripherallycut dual twisted tapes with different cutting pitch ratios (l/y = 0.5, 0.75 and 1.0) were tested for Reynolds numbers in the range of 5400 to 14,000. The experimental results showed thatNusselt number and friction factor of the tubes fitted with PDTswere considerably higher than those of the plain tube and those of the tubes with single twisted tape (ST) and dual twisted tapes (DTs). It was found that PDTs with l/y = 0.5, 0.75 and 1.0 gave higher heat transfer rate than the typical DTs, with average Nusselt numbers greater by 12.1%, 7.8% and 3.8%, respectively. For the range investigated, PDTs with the smallest l/y ratio offered the highest thermal performance factor of 1.14.</jats:p> Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes Open Engineering |
spellingShingle | Changcharoen, W., Somravysin, P., Eiamsa-ard, S., Open Engineering, Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes, Electrical and Electronic Engineering, Mechanical Engineering, Aerospace Engineering, General Materials Science, Civil and Structural Engineering, Environmental Engineering |
title | Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_full | Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_fullStr | Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_full_unstemmed | Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_short | Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_sort | thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
title_unstemmed | Thermal and fluid flow characteristics in a tube equipped with peripherally-cut dual twisted tapes |
topic | Electrical and Electronic Engineering, Mechanical Engineering, Aerospace Engineering, General Materials Science, Civil and Structural Engineering, Environmental Engineering |
url | http://dx.doi.org/10.1515/eng-2015-0009 |