Journal of Veterinary Internal Medicine
Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
General Veterinary
author_sort markovic, lauren e.
spelling Markovic, Lauren E. Scansen, Brian A. 0891-6640 1939-1676 Wiley General Veterinary http://dx.doi.org/10.1111/jvim.15082 <jats:sec><jats:title>Background</jats:title><jats:p>Different methods to perform reference calibration of an angiographic image exist; however, a prospective comparison of calibration methods has yet to be investigated in veterinary medicine.</jats:p></jats:sec><jats:sec><jats:title>Objective</jats:title><jats:p>To compare angiographic measurements using two commonly employed reference calibration methods, an esophageal pigtail marker catheter (EC) versus a radiopaque table ruler (TR).</jats:p></jats:sec><jats:sec><jats:title>Animals</jats:title><jats:p>Thirty‐five client‐owned dogs undergoing transcatheter intervention.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Prospective comparison study. Two reference calibration methods, EC and TR, were recorded in dogs undergoing transcatheter procedures from May 2016 to July 2017. Relevant measurements were performed in triplicate and averaged after image calibration to either EC or TR. Comparisons between methods were made by correlation, paired <jats:italic>t</jats:italic>‐test, the method of Bland and Altman, and Passing‐Bablok regression.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>A total of 39 angiographic structures were measured. Interventions included balloon pulmonary valvuloplasty (n = 21), patent ductus arteriosus occlusion (n = 11), subaortic or sub‐pulmonary balloon dilatation (n = 4), and cor triatriatum membranostomy (n = 3). Angiographic measurements were larger when calibrated to EC versus TR (<jats:italic>P</jats:italic> &lt; .0001). The mean bias was 0.86 mm, with greater bias for larger measurements. The EC measurements were ∼10% greater than TR based on regression analysis. Weight was correlated to the difference between methods (ρ = 0.55, <jats:italic>P</jats:italic> = .0003).</jats:p></jats:sec><jats:sec><jats:title>Conclusions and Clinical Importance</jats:title><jats:p>Angiographic image calibration using a ruler placed on the fluoroscopy table underestimates the size of a structure by ∼10% as compared with a marker catheter placed within the esophagus. This effect is greatest when measuring larger structures such as the pulmonary valve annulus and in larger dogs.</jats:p></jats:sec> Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs Journal of Veterinary Internal Medicine
doi_str_mv 10.1111/jvim.15082
facet_avail Online
Free
format ElectronicArticle
fullrecord blob:ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTExMS9qdmltLjE1MDgy
id ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTExMS9qdmltLjE1MDgy
institution DE-15
DE-Pl11
DE-Rs1
DE-105
DE-14
DE-Ch1
DE-L229
DE-D275
DE-Bn3
DE-Brt1
DE-Zwi2
DE-D161
DE-Gla1
DE-Zi4
imprint Wiley, 2018
imprint_str_mv Wiley, 2018
issn 0891-6640
1939-1676
issn_str_mv 0891-6640
1939-1676
language English
mega_collection Wiley (CrossRef)
match_str markovic2018effectofcalibrationmethodsontheaccuracyofangiographicmeasurementsduringtranscatheterproceduresindogs
publishDateSort 2018
publisher Wiley
recordtype ai
record_format ai
series Journal of Veterinary Internal Medicine
source_id 49
title Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_unstemmed Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_full Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_fullStr Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_full_unstemmed Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_short Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_sort effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
topic General Veterinary
url http://dx.doi.org/10.1111/jvim.15082
publishDate 2018
physical 956-961
description <jats:sec><jats:title>Background</jats:title><jats:p>Different methods to perform reference calibration of an angiographic image exist; however, a prospective comparison of calibration methods has yet to be investigated in veterinary medicine.</jats:p></jats:sec><jats:sec><jats:title>Objective</jats:title><jats:p>To compare angiographic measurements using two commonly employed reference calibration methods, an esophageal pigtail marker catheter (EC) versus a radiopaque table ruler (TR).</jats:p></jats:sec><jats:sec><jats:title>Animals</jats:title><jats:p>Thirty‐five client‐owned dogs undergoing transcatheter intervention.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Prospective comparison study. Two reference calibration methods, EC and TR, were recorded in dogs undergoing transcatheter procedures from May 2016 to July 2017. Relevant measurements were performed in triplicate and averaged after image calibration to either EC or TR. Comparisons between methods were made by correlation, paired <jats:italic>t</jats:italic>‐test, the method of Bland and Altman, and Passing‐Bablok regression.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>A total of 39 angiographic structures were measured. Interventions included balloon pulmonary valvuloplasty (n = 21), patent ductus arteriosus occlusion (n = 11), subaortic or sub‐pulmonary balloon dilatation (n = 4), and cor triatriatum membranostomy (n = 3). Angiographic measurements were larger when calibrated to EC versus TR (<jats:italic>P</jats:italic> &lt; .0001). The mean bias was 0.86 mm, with greater bias for larger measurements. The EC measurements were ∼10% greater than TR based on regression analysis. Weight was correlated to the difference between methods (ρ = 0.55, <jats:italic>P</jats:italic> = .0003).</jats:p></jats:sec><jats:sec><jats:title>Conclusions and Clinical Importance</jats:title><jats:p>Angiographic image calibration using a ruler placed on the fluoroscopy table underestimates the size of a structure by ∼10% as compared with a marker catheter placed within the esophagus. This effect is greatest when measuring larger structures such as the pulmonary valve annulus and in larger dogs.</jats:p></jats:sec>
container_issue 3
container_start_page 956
container_title Journal of Veterinary Internal Medicine
container_volume 32
format_de105 Article, E-Article
format_de14 Article, E-Article
format_de15 Article, E-Article
format_de520 Article, E-Article
format_de540 Article, E-Article
format_dech1 Article, E-Article
format_ded117 Article, E-Article
format_degla1 E-Article
format_del152 Buch
format_del189 Article, E-Article
format_dezi4 Article
format_dezwi2 Article, E-Article
format_finc Article, E-Article
format_nrw Article, E-Article
_version_ 1792334349507493901
geogr_code not assigned
last_indexed 2024-03-01T14:27:11.682Z
geogr_code_person not assigned
openURL url_ver=Z39.88-2004&ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fvufind.svn.sourceforge.net%3Agenerator&rft.title=Effect+of+calibration+methods+on+the+accuracy+of+angiographic+measurements+during+transcatheter+procedures+in+dogs&rft.date=2018-05-01&genre=article&issn=1939-1676&volume=32&issue=3&spage=956&epage=961&pages=956-961&jtitle=Journal+of+Veterinary+Internal+Medicine&atitle=Effect+of+calibration+methods+on+the+accuracy+of+angiographic+measurements+during+transcatheter+procedures+in+dogs&aulast=Scansen&aufirst=Brian+A.&rft_id=info%3Adoi%2F10.1111%2Fjvim.15082&rft.language%5B0%5D=eng
SOLR
_version_ 1792334349507493901
author Markovic, Lauren E., Scansen, Brian A.
author_facet Markovic, Lauren E., Scansen, Brian A., Markovic, Lauren E., Scansen, Brian A.
author_sort markovic, lauren e.
container_issue 3
container_start_page 956
container_title Journal of Veterinary Internal Medicine
container_volume 32
description <jats:sec><jats:title>Background</jats:title><jats:p>Different methods to perform reference calibration of an angiographic image exist; however, a prospective comparison of calibration methods has yet to be investigated in veterinary medicine.</jats:p></jats:sec><jats:sec><jats:title>Objective</jats:title><jats:p>To compare angiographic measurements using two commonly employed reference calibration methods, an esophageal pigtail marker catheter (EC) versus a radiopaque table ruler (TR).</jats:p></jats:sec><jats:sec><jats:title>Animals</jats:title><jats:p>Thirty‐five client‐owned dogs undergoing transcatheter intervention.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Prospective comparison study. Two reference calibration methods, EC and TR, were recorded in dogs undergoing transcatheter procedures from May 2016 to July 2017. Relevant measurements were performed in triplicate and averaged after image calibration to either EC or TR. Comparisons between methods were made by correlation, paired <jats:italic>t</jats:italic>‐test, the method of Bland and Altman, and Passing‐Bablok regression.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>A total of 39 angiographic structures were measured. Interventions included balloon pulmonary valvuloplasty (n = 21), patent ductus arteriosus occlusion (n = 11), subaortic or sub‐pulmonary balloon dilatation (n = 4), and cor triatriatum membranostomy (n = 3). Angiographic measurements were larger when calibrated to EC versus TR (<jats:italic>P</jats:italic> &lt; .0001). The mean bias was 0.86 mm, with greater bias for larger measurements. The EC measurements were ∼10% greater than TR based on regression analysis. Weight was correlated to the difference between methods (ρ = 0.55, <jats:italic>P</jats:italic> = .0003).</jats:p></jats:sec><jats:sec><jats:title>Conclusions and Clinical Importance</jats:title><jats:p>Angiographic image calibration using a ruler placed on the fluoroscopy table underestimates the size of a structure by ∼10% as compared with a marker catheter placed within the esophagus. This effect is greatest when measuring larger structures such as the pulmonary valve annulus and in larger dogs.</jats:p></jats:sec>
doi_str_mv 10.1111/jvim.15082
facet_avail Online, Free
format ElectronicArticle
format_de105 Article, E-Article
format_de14 Article, E-Article
format_de15 Article, E-Article
format_de520 Article, E-Article
format_de540 Article, E-Article
format_dech1 Article, E-Article
format_ded117 Article, E-Article
format_degla1 E-Article
format_del152 Buch
format_del189 Article, E-Article
format_dezi4 Article
format_dezwi2 Article, E-Article
format_finc Article, E-Article
format_nrw Article, E-Article
geogr_code not assigned
geogr_code_person not assigned
id ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTExMS9qdmltLjE1MDgy
imprint Wiley, 2018
imprint_str_mv Wiley, 2018
institution DE-15, DE-Pl11, DE-Rs1, DE-105, DE-14, DE-Ch1, DE-L229, DE-D275, DE-Bn3, DE-Brt1, DE-Zwi2, DE-D161, DE-Gla1, DE-Zi4
issn 0891-6640, 1939-1676
issn_str_mv 0891-6640, 1939-1676
language English
last_indexed 2024-03-01T14:27:11.682Z
match_str markovic2018effectofcalibrationmethodsontheaccuracyofangiographicmeasurementsduringtranscatheterproceduresindogs
mega_collection Wiley (CrossRef)
physical 956-961
publishDate 2018
publishDateSort 2018
publisher Wiley
record_format ai
recordtype ai
series Journal of Veterinary Internal Medicine
source_id 49
spelling Markovic, Lauren E. Scansen, Brian A. 0891-6640 1939-1676 Wiley General Veterinary http://dx.doi.org/10.1111/jvim.15082 <jats:sec><jats:title>Background</jats:title><jats:p>Different methods to perform reference calibration of an angiographic image exist; however, a prospective comparison of calibration methods has yet to be investigated in veterinary medicine.</jats:p></jats:sec><jats:sec><jats:title>Objective</jats:title><jats:p>To compare angiographic measurements using two commonly employed reference calibration methods, an esophageal pigtail marker catheter (EC) versus a radiopaque table ruler (TR).</jats:p></jats:sec><jats:sec><jats:title>Animals</jats:title><jats:p>Thirty‐five client‐owned dogs undergoing transcatheter intervention.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Prospective comparison study. Two reference calibration methods, EC and TR, were recorded in dogs undergoing transcatheter procedures from May 2016 to July 2017. Relevant measurements were performed in triplicate and averaged after image calibration to either EC or TR. Comparisons between methods were made by correlation, paired <jats:italic>t</jats:italic>‐test, the method of Bland and Altman, and Passing‐Bablok regression.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>A total of 39 angiographic structures were measured. Interventions included balloon pulmonary valvuloplasty (n = 21), patent ductus arteriosus occlusion (n = 11), subaortic or sub‐pulmonary balloon dilatation (n = 4), and cor triatriatum membranostomy (n = 3). Angiographic measurements were larger when calibrated to EC versus TR (<jats:italic>P</jats:italic> &lt; .0001). The mean bias was 0.86 mm, with greater bias for larger measurements. The EC measurements were ∼10% greater than TR based on regression analysis. Weight was correlated to the difference between methods (ρ = 0.55, <jats:italic>P</jats:italic> = .0003).</jats:p></jats:sec><jats:sec><jats:title>Conclusions and Clinical Importance</jats:title><jats:p>Angiographic image calibration using a ruler placed on the fluoroscopy table underestimates the size of a structure by ∼10% as compared with a marker catheter placed within the esophagus. This effect is greatest when measuring larger structures such as the pulmonary valve annulus and in larger dogs.</jats:p></jats:sec> Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs Journal of Veterinary Internal Medicine
spellingShingle Markovic, Lauren E., Scansen, Brian A., Journal of Veterinary Internal Medicine, Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs, General Veterinary
title Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_full Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_fullStr Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_full_unstemmed Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_short Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_sort effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_unstemmed Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
topic General Veterinary
url http://dx.doi.org/10.1111/jvim.15082