Eintrag weiter verarbeiten
Robust, routine haematology reference ranges for healthy adults
Gespeichert in:
Zeitschriftentitel: | International Journal of Laboratory Hematology |
---|---|
Personen und Körperschaften: | , , , , , , , |
In: | International Journal of Laboratory Hematology, 29, 2007, 4, S. 279-283 |
Format: | E-Article |
Sprache: | Englisch |
veröffentlicht: |
Wiley
|
Schlagwörter: |
author_facet |
WAKEMAN, L. AL‐ISMAIL, S. BENTON, A. BEDDALL, A. GIBBS, A. HARTNELL, S. MORRIS, K. MUNRO, R. WAKEMAN, L. AL‐ISMAIL, S. BENTON, A. BEDDALL, A. GIBBS, A. HARTNELL, S. MORRIS, K. MUNRO, R. |
---|---|
author |
WAKEMAN, L. AL‐ISMAIL, S. BENTON, A. BEDDALL, A. GIBBS, A. HARTNELL, S. MORRIS, K. MUNRO, R. |
spellingShingle |
WAKEMAN, L. AL‐ISMAIL, S. BENTON, A. BEDDALL, A. GIBBS, A. HARTNELL, S. MORRIS, K. MUNRO, R. International Journal of Laboratory Hematology Robust, routine haematology reference ranges for healthy adults Biochemistry (medical) Clinical Biochemistry Hematology General Medicine |
author_sort |
wakeman, l. |
spelling |
WAKEMAN, L. AL‐ISMAIL, S. BENTON, A. BEDDALL, A. GIBBS, A. HARTNELL, S. MORRIS, K. MUNRO, R. 1751-5521 1751-553X Wiley Biochemistry (medical) Clinical Biochemistry Hematology General Medicine http://dx.doi.org/10.1111/j.1365-2257.2006.00883.x <jats:title>Summary</jats:title><jats:p>Accurate, reliable laboratory reference ranges are essential for effective clinical evaluation and monitoring. We present robust reference ranges established for haematology, coagulation and haematinic parameters using the Sysmex XE 2100, CA 1500 and Beckman–Coulter Access analysers. Blood samples were taken from 250 healthy laboratory personnel and routine haematology, coagulation and haematinic parameter analysis performed. Our data represent findings from an extensive study to establish reference ranges in healthy adults.</jats:p> Robust, routine haematology reference ranges for healthy adults International Journal of Laboratory Hematology |
doi_str_mv |
10.1111/j.1365-2257.2006.00883.x |
facet_avail |
Online |
finc_class_facet |
Medizin Biologie Chemie und Pharmazie |
format |
ElectronicArticle |
fullrecord |
blob:ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTExMS9qLjEzNjUtMjI1Ny4yMDA2LjAwODgzLng |
id |
ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTExMS9qLjEzNjUtMjI1Ny4yMDA2LjAwODgzLng |
institution |
DE-D275 DE-Bn3 DE-Brt1 DE-D161 DE-Gla1 DE-Zi4 DE-15 DE-Pl11 DE-Rs1 DE-105 DE-14 DE-Ch1 DE-L229 |
imprint |
Wiley, 2007 |
imprint_str_mv |
Wiley, 2007 |
issn |
1751-5521 1751-553X |
issn_str_mv |
1751-5521 1751-553X |
language |
English |
mega_collection |
Wiley (CrossRef) |
match_str |
wakeman2007robustroutinehaematologyreferencerangesforhealthyadults |
publishDateSort |
2007 |
publisher |
Wiley |
recordtype |
ai |
record_format |
ai |
series |
International Journal of Laboratory Hematology |
source_id |
49 |
title |
Robust, routine haematology reference ranges for healthy adults |
title_unstemmed |
Robust, routine haematology reference ranges for healthy adults |
title_full |
Robust, routine haematology reference ranges for healthy adults |
title_fullStr |
Robust, routine haematology reference ranges for healthy adults |
title_full_unstemmed |
Robust, routine haematology reference ranges for healthy adults |
title_short |
Robust, routine haematology reference ranges for healthy adults |
title_sort |
robust, routine haematology reference ranges for healthy adults |
topic |
Biochemistry (medical) Clinical Biochemistry Hematology General Medicine |
url |
http://dx.doi.org/10.1111/j.1365-2257.2006.00883.x |
publishDate |
2007 |
physical |
279-283 |
description |
<jats:title>Summary</jats:title><jats:p>Accurate, reliable laboratory reference ranges are essential for effective clinical evaluation and monitoring. We present robust reference ranges established for haematology, coagulation and haematinic parameters using the Sysmex XE 2100, CA 1500 and Beckman–Coulter Access analysers. Blood samples were taken from 250 healthy laboratory personnel and routine haematology, coagulation and haematinic parameter analysis performed. Our data represent findings from an extensive study to establish reference ranges in healthy adults.</jats:p> |
container_issue |
4 |
container_start_page |
279 |
container_title |
International Journal of Laboratory Hematology |
container_volume |
29 |
format_de105 |
Article, E-Article |
format_de14 |
Article, E-Article |
format_de15 |
Article, E-Article |
format_de520 |
Article, E-Article |
format_de540 |
Article, E-Article |
format_dech1 |
Article, E-Article |
format_ded117 |
Article, E-Article |
format_degla1 |
E-Article |
format_del152 |
Buch |
format_del189 |
Article, E-Article |
format_dezi4 |
Article |
format_dezwi2 |
Article, E-Article |
format_finc |
Article, E-Article |
format_nrw |
Article, E-Article |
_version_ |
1792341349269241861 |
geogr_code |
not assigned |
last_indexed |
2024-03-01T16:18:29.564Z |
geogr_code_person |
not assigned |
openURL |
url_ver=Z39.88-2004&ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fvufind.svn.sourceforge.net%3Agenerator&rft.title=Robust%2C+routine+haematology+reference+ranges+for+healthy+adults&rft.date=2007-08-01&genre=article&issn=1751-553X&volume=29&issue=4&spage=279&epage=283&pages=279-283&jtitle=International+Journal+of+Laboratory+Hematology&atitle=Robust%2C+routine+haematology+reference+ranges+for+healthy+adults&aulast=MUNRO&aufirst=R.&rft_id=info%3Adoi%2F10.1111%2Fj.1365-2257.2006.00883.x&rft.language%5B0%5D=eng |
SOLR | |
_version_ | 1792341349269241861 |
author | WAKEMAN, L., AL‐ISMAIL, S., BENTON, A., BEDDALL, A., GIBBS, A., HARTNELL, S., MORRIS, K., MUNRO, R. |
author_facet | WAKEMAN, L., AL‐ISMAIL, S., BENTON, A., BEDDALL, A., GIBBS, A., HARTNELL, S., MORRIS, K., MUNRO, R., WAKEMAN, L., AL‐ISMAIL, S., BENTON, A., BEDDALL, A., GIBBS, A., HARTNELL, S., MORRIS, K., MUNRO, R. |
author_sort | wakeman, l. |
container_issue | 4 |
container_start_page | 279 |
container_title | International Journal of Laboratory Hematology |
container_volume | 29 |
description | <jats:title>Summary</jats:title><jats:p>Accurate, reliable laboratory reference ranges are essential for effective clinical evaluation and monitoring. We present robust reference ranges established for haematology, coagulation and haematinic parameters using the Sysmex XE 2100, CA 1500 and Beckman–Coulter Access analysers. Blood samples were taken from 250 healthy laboratory personnel and routine haematology, coagulation and haematinic parameter analysis performed. Our data represent findings from an extensive study to establish reference ranges in healthy adults.</jats:p> |
doi_str_mv | 10.1111/j.1365-2257.2006.00883.x |
facet_avail | Online |
finc_class_facet | Medizin, Biologie, Chemie und Pharmazie |
format | ElectronicArticle |
format_de105 | Article, E-Article |
format_de14 | Article, E-Article |
format_de15 | Article, E-Article |
format_de520 | Article, E-Article |
format_de540 | Article, E-Article |
format_dech1 | Article, E-Article |
format_ded117 | Article, E-Article |
format_degla1 | E-Article |
format_del152 | Buch |
format_del189 | Article, E-Article |
format_dezi4 | Article |
format_dezwi2 | Article, E-Article |
format_finc | Article, E-Article |
format_nrw | Article, E-Article |
geogr_code | not assigned |
geogr_code_person | not assigned |
id | ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTExMS9qLjEzNjUtMjI1Ny4yMDA2LjAwODgzLng |
imprint | Wiley, 2007 |
imprint_str_mv | Wiley, 2007 |
institution | DE-D275, DE-Bn3, DE-Brt1, DE-D161, DE-Gla1, DE-Zi4, DE-15, DE-Pl11, DE-Rs1, DE-105, DE-14, DE-Ch1, DE-L229 |
issn | 1751-5521, 1751-553X |
issn_str_mv | 1751-5521, 1751-553X |
language | English |
last_indexed | 2024-03-01T16:18:29.564Z |
match_str | wakeman2007robustroutinehaematologyreferencerangesforhealthyadults |
mega_collection | Wiley (CrossRef) |
physical | 279-283 |
publishDate | 2007 |
publishDateSort | 2007 |
publisher | Wiley |
record_format | ai |
recordtype | ai |
series | International Journal of Laboratory Hematology |
source_id | 49 |
spelling | WAKEMAN, L. AL‐ISMAIL, S. BENTON, A. BEDDALL, A. GIBBS, A. HARTNELL, S. MORRIS, K. MUNRO, R. 1751-5521 1751-553X Wiley Biochemistry (medical) Clinical Biochemistry Hematology General Medicine http://dx.doi.org/10.1111/j.1365-2257.2006.00883.x <jats:title>Summary</jats:title><jats:p>Accurate, reliable laboratory reference ranges are essential for effective clinical evaluation and monitoring. We present robust reference ranges established for haematology, coagulation and haematinic parameters using the Sysmex XE 2100, CA 1500 and Beckman–Coulter Access analysers. Blood samples were taken from 250 healthy laboratory personnel and routine haematology, coagulation and haematinic parameter analysis performed. Our data represent findings from an extensive study to establish reference ranges in healthy adults.</jats:p> Robust, routine haematology reference ranges for healthy adults International Journal of Laboratory Hematology |
spellingShingle | WAKEMAN, L., AL‐ISMAIL, S., BENTON, A., BEDDALL, A., GIBBS, A., HARTNELL, S., MORRIS, K., MUNRO, R., International Journal of Laboratory Hematology, Robust, routine haematology reference ranges for healthy adults, Biochemistry (medical), Clinical Biochemistry, Hematology, General Medicine |
title | Robust, routine haematology reference ranges for healthy adults |
title_full | Robust, routine haematology reference ranges for healthy adults |
title_fullStr | Robust, routine haematology reference ranges for healthy adults |
title_full_unstemmed | Robust, routine haematology reference ranges for healthy adults |
title_short | Robust, routine haematology reference ranges for healthy adults |
title_sort | robust, routine haematology reference ranges for healthy adults |
title_unstemmed | Robust, routine haematology reference ranges for healthy adults |
topic | Biochemistry (medical), Clinical Biochemistry, Hematology, General Medicine |
url | http://dx.doi.org/10.1111/j.1365-2257.2006.00883.x |