author_facet Nielsen, S. L.
Lassen, N. A.
Nielsen, S. L.
Lassen, N. A.
author Nielsen, S. L.
Lassen, N. A.
spellingShingle Nielsen, S. L.
Lassen, N. A.
Journal of Applied Physiology
Measurement of digital blood pressure after local cooling
Physiology (medical)
Physiology
author_sort nielsen, s. l.
spelling Nielsen, S. L. Lassen, N. A. 8750-7587 1522-1601 American Physiological Society Physiology (medical) Physiology http://dx.doi.org/10.1152/jappl.1977.43.5.907 <jats:p> A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women. In patients with primary or secondary Raynaud's phenomenon, the arterial tone showed an abrupt increase that most often led to complete closure of the digital arteries. The pathological response was expressed as an increased threshold temperature or a well-defined closing temperature that showed only small variations during standardized conditions. </jats:p> Measurement of digital blood pressure after local cooling Journal of Applied Physiology
doi_str_mv 10.1152/jappl.1977.43.5.907
facet_avail Online
finc_class_facet Biologie
format ElectronicArticle
fullrecord blob:ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTE1Mi9qYXBwbC4xOTc3LjQzLjUuOTA3
id ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTE1Mi9qYXBwbC4xOTc3LjQzLjUuOTA3
institution DE-D275
DE-Bn3
DE-Brt1
DE-D161
DE-Gla1
DE-Zi4
DE-15
DE-Pl11
DE-Rs1
DE-14
DE-Ch1
DE-L229
imprint American Physiological Society, 1977
imprint_str_mv American Physiological Society, 1977
issn 8750-7587
1522-1601
issn_str_mv 8750-7587
1522-1601
language English
mega_collection American Physiological Society (CrossRef)
match_str nielsen1977measurementofdigitalbloodpressureafterlocalcooling
publishDateSort 1977
publisher American Physiological Society
recordtype ai
record_format ai
series Journal of Applied Physiology
source_id 49
title Measurement of digital blood pressure after local cooling
title_unstemmed Measurement of digital blood pressure after local cooling
title_full Measurement of digital blood pressure after local cooling
title_fullStr Measurement of digital blood pressure after local cooling
title_full_unstemmed Measurement of digital blood pressure after local cooling
title_short Measurement of digital blood pressure after local cooling
title_sort measurement of digital blood pressure after local cooling
topic Physiology (medical)
Physiology
url http://dx.doi.org/10.1152/jappl.1977.43.5.907
publishDate 1977
physical 907-910
description <jats:p> A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women. In patients with primary or secondary Raynaud's phenomenon, the arterial tone showed an abrupt increase that most often led to complete closure of the digital arteries. The pathological response was expressed as an increased threshold temperature or a well-defined closing temperature that showed only small variations during standardized conditions. </jats:p>
container_issue 5
container_start_page 907
container_title Journal of Applied Physiology
container_volume 43
format_de105 Article, E-Article
format_de14 Article, E-Article
format_de15 Article, E-Article
format_de520 Article, E-Article
format_de540 Article, E-Article
format_dech1 Article, E-Article
format_ded117 Article, E-Article
format_degla1 E-Article
format_del152 Buch
format_del189 Article, E-Article
format_dezi4 Article
format_dezwi2 Article, E-Article
format_finc Article, E-Article
format_nrw Article, E-Article
_version_ 1792341680832118791
geogr_code not assigned
last_indexed 2024-03-01T16:21:57.498Z
geogr_code_person not assigned
openURL url_ver=Z39.88-2004&ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fvufind.svn.sourceforge.net%3Agenerator&rft.title=Measurement+of+digital+blood+pressure+after+local+cooling&rft.date=1977-11-01&genre=article&issn=1522-1601&volume=43&issue=5&spage=907&epage=910&pages=907-910&jtitle=Journal+of+Applied+Physiology&atitle=Measurement+of+digital+blood+pressure+after+local+cooling&aulast=Lassen&aufirst=N.+A.&rft_id=info%3Adoi%2F10.1152%2Fjappl.1977.43.5.907&rft.language%5B0%5D=eng
SOLR
_version_ 1792341680832118791
author Nielsen, S. L., Lassen, N. A.
author_facet Nielsen, S. L., Lassen, N. A., Nielsen, S. L., Lassen, N. A.
author_sort nielsen, s. l.
container_issue 5
container_start_page 907
container_title Journal of Applied Physiology
container_volume 43
description <jats:p> A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women. In patients with primary or secondary Raynaud's phenomenon, the arterial tone showed an abrupt increase that most often led to complete closure of the digital arteries. The pathological response was expressed as an increased threshold temperature or a well-defined closing temperature that showed only small variations during standardized conditions. </jats:p>
doi_str_mv 10.1152/jappl.1977.43.5.907
facet_avail Online
finc_class_facet Biologie
format ElectronicArticle
format_de105 Article, E-Article
format_de14 Article, E-Article
format_de15 Article, E-Article
format_de520 Article, E-Article
format_de540 Article, E-Article
format_dech1 Article, E-Article
format_ded117 Article, E-Article
format_degla1 E-Article
format_del152 Buch
format_del189 Article, E-Article
format_dezi4 Article
format_dezwi2 Article, E-Article
format_finc Article, E-Article
format_nrw Article, E-Article
geogr_code not assigned
geogr_code_person not assigned
id ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTE1Mi9qYXBwbC4xOTc3LjQzLjUuOTA3
imprint American Physiological Society, 1977
imprint_str_mv American Physiological Society, 1977
institution DE-D275, DE-Bn3, DE-Brt1, DE-D161, DE-Gla1, DE-Zi4, DE-15, DE-Pl11, DE-Rs1, DE-14, DE-Ch1, DE-L229
issn 8750-7587, 1522-1601
issn_str_mv 8750-7587, 1522-1601
language English
last_indexed 2024-03-01T16:21:57.498Z
match_str nielsen1977measurementofdigitalbloodpressureafterlocalcooling
mega_collection American Physiological Society (CrossRef)
physical 907-910
publishDate 1977
publishDateSort 1977
publisher American Physiological Society
record_format ai
recordtype ai
series Journal of Applied Physiology
source_id 49
spelling Nielsen, S. L. Lassen, N. A. 8750-7587 1522-1601 American Physiological Society Physiology (medical) Physiology http://dx.doi.org/10.1152/jappl.1977.43.5.907 <jats:p> A double-inlet plastic cuff was designed for local cooling and systolic blood pressure measurement on the middle phalanx of the fingers. With a tourniquet on the proximal phalanx of one finger, cooling for 5 min made the digital artery temperature equal the skin temperature. The difference between the systolic pressure in a control finger and in the cooled finger give the reopening pressure in the digital arteries. At 30, 25, 20, 15, and 10 degrees C, respectively the percent decrease of the finger pressure was 0.2 (0.2), 1.5 (2.5), 8.5 (3.7), 11.4 (3.4), and 15.3 (3.1) in normal young women. In patients with primary or secondary Raynaud's phenomenon, the arterial tone showed an abrupt increase that most often led to complete closure of the digital arteries. The pathological response was expressed as an increased threshold temperature or a well-defined closing temperature that showed only small variations during standardized conditions. </jats:p> Measurement of digital blood pressure after local cooling Journal of Applied Physiology
spellingShingle Nielsen, S. L., Lassen, N. A., Journal of Applied Physiology, Measurement of digital blood pressure after local cooling, Physiology (medical), Physiology
title Measurement of digital blood pressure after local cooling
title_full Measurement of digital blood pressure after local cooling
title_fullStr Measurement of digital blood pressure after local cooling
title_full_unstemmed Measurement of digital blood pressure after local cooling
title_short Measurement of digital blood pressure after local cooling
title_sort measurement of digital blood pressure after local cooling
title_unstemmed Measurement of digital blood pressure after local cooling
topic Physiology (medical), Physiology
url http://dx.doi.org/10.1152/jappl.1977.43.5.907