Medical Physics
Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
General Medicine
author_sort jang, deok hyun
spelling Jang, Deok Hyun Da Silva, Eric Tavakkoli, Jahan Slatkovska, Lubomira Cheung, Angela M. Pejović‐Milić, Ana 0094-2405 2473-4209 Wiley General Medicine http://dx.doi.org/10.1002/mp.12641 <jats:sec><jats:title>Purpose</jats:title><jats:p>Dual‐energy X‐ray absorptiometry (DXA) is the gold standard technique to measure areal bone mineral density (aBMD) for the diagnosis of osteoporosis. Because DXA relies on the attenuation of photon to estimate aBMD, deposition of bone‐seeking metallic elements such as strontium, lead, and aluminum that differ in atomic numbers from calcium can cause inaccurate estimation of aBMD. Quantitative ultrasound (QUS) is another technique available to assess bone health by measuring broadband ultrasound attenuation (BUA), speed of sound (SOS), and an empirically derived quantity called stiffness index (SI). Because the acoustic properties are not prone to significant change due to changes in microscopic atomic composition of bone, it is hypothesized that QUS is unaffected by the presence of bone‐seeking elements in the bone. The objective of this study was to investigate the effect of strontium, lead, and aluminum on DXA‐derived aBMD and QUS parameters using bone‐mimicking phantoms compatible with both techniques.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Bone‐mimicking phantoms were produced by homogeneously mixing finely powdered hydroxyapatite compounds that contain varying concentrations of strontium, lead, or aluminum with porcine gelatin solution. Seven strontium‐substituted phantoms were produced with varying molar ratio of Sr/(Sr + Ca) ranging from 0% to 2%. Four lead‐doped phantoms and four aluminum‐doped phantoms were constructed with the respective analyte concentrations ranging from 50 to 200 ppm. An additional 0 ppm phantom was produced to be used as a baseline for the lead and aluminum phantom measurements. All phantoms had uniform volumetric bone mineral density (vBMD) of 200 mg/cm<jats:sup>3</jats:sup>, and were assessed using a Hologic Horizon<jats:sup>®</jats:sup> DXA device and a Hologic Sahara<jats:sup>®</jats:sup> QUS device. Furthermore, theoretical aBMD bias for mol/mol% substitution of calcium with the three bone‐seeking elements was calculated.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Strong positive linear relationship was found between aBMD measured by DXA and strontium concentration (<jats:italic>P</jats:italic> &lt; 0.001, <jats:italic>r</jats:italic> = 0.995). From the measurement of lead and aluminum phantoms using DXA, no statistically significant relationship was observed between aBMD and the analyte concentrations. For the QUS system, with an exception of BUA and lead concentration that exhibited statistically significant relationship (<jats:italic>P</jats:italic> &lt; 0.038, <jats:italic>r</jats:italic> = 0.899), no statistically significant change was observed in all QUS parameters with respect to the clinically relevant concentration of all three elements. The calculated theoretical aBMD bias induced by 1 mol/mol% substitution of calcium with strontium, lead, and aluminum were 10.8%, 4.6%, and −0.7%, respectively.</jats:p></jats:sec><jats:sec><jats:title>Conclusion</jats:title><jats:p>aBMD measured by DXA was prone to overestimation in the presence of strontium, but acoustic parameters measured by QUS are independent of strontium concentration. The deviation in aBMD induced by the clinically relevant concentrations of lead and aluminum under 200 ppm could not be detected using the Hologic Horizon<jats:sup>®</jats:sup> DXA device. Furthermore, the SI measured by the QUS system was not affected by lead or aluminum concentrations used in this study.</jats:p></jats:sec> Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study Medical Physics
doi_str_mv 10.1002/mp.12641
facet_avail Online
format ElectronicArticle
fullrecord blob:ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTAwMi9tcC4xMjY0MQ
id ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTAwMi9tcC4xMjY0MQ
institution DE-Bn3
DE-Brt1
DE-D161
DE-Gla1
DE-Zi4
DE-15
DE-Pl11
DE-Rs1
DE-105
DE-14
DE-Ch1
DE-L229
DE-D275
imprint Wiley, 2018
imprint_str_mv Wiley, 2018
issn 0094-2405
2473-4209
issn_str_mv 0094-2405
2473-4209
language English
mega_collection Wiley (CrossRef)
match_str jang2018assessmentoftheeffectofstrontiumleadandaluminuminboneondualenergyxrayabsorptiometryandquantitativeultrasoundmeasurementsaphantomstudy
publishDateSort 2018
publisher Wiley
recordtype ai
record_format ai
series Medical Physics
source_id 49
title Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_unstemmed Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_full Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_fullStr Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_full_unstemmed Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_short Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_sort assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: a phantom study
topic General Medicine
url http://dx.doi.org/10.1002/mp.12641
publishDate 2018
physical 81-91
description <jats:sec><jats:title>Purpose</jats:title><jats:p>Dual‐energy X‐ray absorptiometry (DXA) is the gold standard technique to measure areal bone mineral density (aBMD) for the diagnosis of osteoporosis. Because DXA relies on the attenuation of photon to estimate aBMD, deposition of bone‐seeking metallic elements such as strontium, lead, and aluminum that differ in atomic numbers from calcium can cause inaccurate estimation of aBMD. Quantitative ultrasound (QUS) is another technique available to assess bone health by measuring broadband ultrasound attenuation (BUA), speed of sound (SOS), and an empirically derived quantity called stiffness index (SI). Because the acoustic properties are not prone to significant change due to changes in microscopic atomic composition of bone, it is hypothesized that QUS is unaffected by the presence of bone‐seeking elements in the bone. The objective of this study was to investigate the effect of strontium, lead, and aluminum on DXA‐derived aBMD and QUS parameters using bone‐mimicking phantoms compatible with both techniques.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Bone‐mimicking phantoms were produced by homogeneously mixing finely powdered hydroxyapatite compounds that contain varying concentrations of strontium, lead, or aluminum with porcine gelatin solution. Seven strontium‐substituted phantoms were produced with varying molar ratio of Sr/(Sr + Ca) ranging from 0% to 2%. Four lead‐doped phantoms and four aluminum‐doped phantoms were constructed with the respective analyte concentrations ranging from 50 to 200 ppm. An additional 0 ppm phantom was produced to be used as a baseline for the lead and aluminum phantom measurements. All phantoms had uniform volumetric bone mineral density (vBMD) of 200 mg/cm<jats:sup>3</jats:sup>, and were assessed using a Hologic Horizon<jats:sup>®</jats:sup> DXA device and a Hologic Sahara<jats:sup>®</jats:sup> QUS device. Furthermore, theoretical aBMD bias for mol/mol% substitution of calcium with the three bone‐seeking elements was calculated.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Strong positive linear relationship was found between aBMD measured by DXA and strontium concentration (<jats:italic>P</jats:italic> &lt; 0.001, <jats:italic>r</jats:italic> = 0.995). From the measurement of lead and aluminum phantoms using DXA, no statistically significant relationship was observed between aBMD and the analyte concentrations. For the QUS system, with an exception of BUA and lead concentration that exhibited statistically significant relationship (<jats:italic>P</jats:italic> &lt; 0.038, <jats:italic>r</jats:italic> = 0.899), no statistically significant change was observed in all QUS parameters with respect to the clinically relevant concentration of all three elements. The calculated theoretical aBMD bias induced by 1 mol/mol% substitution of calcium with strontium, lead, and aluminum were 10.8%, 4.6%, and −0.7%, respectively.</jats:p></jats:sec><jats:sec><jats:title>Conclusion</jats:title><jats:p>aBMD measured by DXA was prone to overestimation in the presence of strontium, but acoustic parameters measured by QUS are independent of strontium concentration. The deviation in aBMD induced by the clinically relevant concentrations of lead and aluminum under 200 ppm could not be detected using the Hologic Horizon<jats:sup>®</jats:sup> DXA device. Furthermore, the SI measured by the QUS system was not affected by lead or aluminum concentrations used in this study.</jats:p></jats:sec>
container_issue 1
container_start_page 81
container_title Medical Physics
container_volume 45
format_de105 Article, E-Article
format_de14 Article, E-Article
format_de15 Article, E-Article
format_de520 Article, E-Article
format_de540 Article, E-Article
format_dech1 Article, E-Article
format_ded117 Article, E-Article
format_degla1 E-Article
format_del152 Buch
format_del189 Article, E-Article
format_dezi4 Article
format_dezwi2 Article, E-Article
format_finc Article, E-Article
format_nrw Article, E-Article
_version_ 1792333622091448328
geogr_code not assigned
last_indexed 2024-03-01T14:15:38.811Z
geogr_code_person not assigned
openURL url_ver=Z39.88-2004&ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fvufind.svn.sourceforge.net%3Agenerator&rft.title=Assessment+of+the+effect+of+strontium%2C+lead%2C+and+aluminum+in+bone+on+dual%E2%80%90energy+x%E2%80%90ray+absorptiometry+and+quantitative+ultrasound+measurements%3A+A+phantom+study&rft.date=2018-01-01&genre=article&issn=2473-4209&volume=45&issue=1&spage=81&epage=91&pages=81-91&jtitle=Medical+Physics&atitle=Assessment+of+the+effect+of+strontium%2C+lead%2C+and+aluminum+in+bone+on+dual%E2%80%90energy+x%E2%80%90ray+absorptiometry+and+quantitative+ultrasound+measurements%3A+A+phantom+study&aulast=Pejovi%C4%87%E2%80%90Mili%C4%87&aufirst=Ana&rft_id=info%3Adoi%2F10.1002%2Fmp.12641&rft.language%5B0%5D=eng
SOLR
_version_ 1792333622091448328
author Jang, Deok Hyun, Da Silva, Eric, Tavakkoli, Jahan, Slatkovska, Lubomira, Cheung, Angela M., Pejović‐Milić, Ana
author_facet Jang, Deok Hyun, Da Silva, Eric, Tavakkoli, Jahan, Slatkovska, Lubomira, Cheung, Angela M., Pejović‐Milić, Ana, Jang, Deok Hyun, Da Silva, Eric, Tavakkoli, Jahan, Slatkovska, Lubomira, Cheung, Angela M., Pejović‐Milić, Ana
author_sort jang, deok hyun
container_issue 1
container_start_page 81
container_title Medical Physics
container_volume 45
description <jats:sec><jats:title>Purpose</jats:title><jats:p>Dual‐energy X‐ray absorptiometry (DXA) is the gold standard technique to measure areal bone mineral density (aBMD) for the diagnosis of osteoporosis. Because DXA relies on the attenuation of photon to estimate aBMD, deposition of bone‐seeking metallic elements such as strontium, lead, and aluminum that differ in atomic numbers from calcium can cause inaccurate estimation of aBMD. Quantitative ultrasound (QUS) is another technique available to assess bone health by measuring broadband ultrasound attenuation (BUA), speed of sound (SOS), and an empirically derived quantity called stiffness index (SI). Because the acoustic properties are not prone to significant change due to changes in microscopic atomic composition of bone, it is hypothesized that QUS is unaffected by the presence of bone‐seeking elements in the bone. The objective of this study was to investigate the effect of strontium, lead, and aluminum on DXA‐derived aBMD and QUS parameters using bone‐mimicking phantoms compatible with both techniques.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Bone‐mimicking phantoms were produced by homogeneously mixing finely powdered hydroxyapatite compounds that contain varying concentrations of strontium, lead, or aluminum with porcine gelatin solution. Seven strontium‐substituted phantoms were produced with varying molar ratio of Sr/(Sr + Ca) ranging from 0% to 2%. Four lead‐doped phantoms and four aluminum‐doped phantoms were constructed with the respective analyte concentrations ranging from 50 to 200 ppm. An additional 0 ppm phantom was produced to be used as a baseline for the lead and aluminum phantom measurements. All phantoms had uniform volumetric bone mineral density (vBMD) of 200 mg/cm<jats:sup>3</jats:sup>, and were assessed using a Hologic Horizon<jats:sup>®</jats:sup> DXA device and a Hologic Sahara<jats:sup>®</jats:sup> QUS device. Furthermore, theoretical aBMD bias for mol/mol% substitution of calcium with the three bone‐seeking elements was calculated.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Strong positive linear relationship was found between aBMD measured by DXA and strontium concentration (<jats:italic>P</jats:italic> &lt; 0.001, <jats:italic>r</jats:italic> = 0.995). From the measurement of lead and aluminum phantoms using DXA, no statistically significant relationship was observed between aBMD and the analyte concentrations. For the QUS system, with an exception of BUA and lead concentration that exhibited statistically significant relationship (<jats:italic>P</jats:italic> &lt; 0.038, <jats:italic>r</jats:italic> = 0.899), no statistically significant change was observed in all QUS parameters with respect to the clinically relevant concentration of all three elements. The calculated theoretical aBMD bias induced by 1 mol/mol% substitution of calcium with strontium, lead, and aluminum were 10.8%, 4.6%, and −0.7%, respectively.</jats:p></jats:sec><jats:sec><jats:title>Conclusion</jats:title><jats:p>aBMD measured by DXA was prone to overestimation in the presence of strontium, but acoustic parameters measured by QUS are independent of strontium concentration. The deviation in aBMD induced by the clinically relevant concentrations of lead and aluminum under 200 ppm could not be detected using the Hologic Horizon<jats:sup>®</jats:sup> DXA device. Furthermore, the SI measured by the QUS system was not affected by lead or aluminum concentrations used in this study.</jats:p></jats:sec>
doi_str_mv 10.1002/mp.12641
facet_avail Online
format ElectronicArticle
format_de105 Article, E-Article
format_de14 Article, E-Article
format_de15 Article, E-Article
format_de520 Article, E-Article
format_de540 Article, E-Article
format_dech1 Article, E-Article
format_ded117 Article, E-Article
format_degla1 E-Article
format_del152 Buch
format_del189 Article, E-Article
format_dezi4 Article
format_dezwi2 Article, E-Article
format_finc Article, E-Article
format_nrw Article, E-Article
geogr_code not assigned
geogr_code_person not assigned
id ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTAwMi9tcC4xMjY0MQ
imprint Wiley, 2018
imprint_str_mv Wiley, 2018
institution DE-Bn3, DE-Brt1, DE-D161, DE-Gla1, DE-Zi4, DE-15, DE-Pl11, DE-Rs1, DE-105, DE-14, DE-Ch1, DE-L229, DE-D275
issn 0094-2405, 2473-4209
issn_str_mv 0094-2405, 2473-4209
language English
last_indexed 2024-03-01T14:15:38.811Z
match_str jang2018assessmentoftheeffectofstrontiumleadandaluminuminboneondualenergyxrayabsorptiometryandquantitativeultrasoundmeasurementsaphantomstudy
mega_collection Wiley (CrossRef)
physical 81-91
publishDate 2018
publishDateSort 2018
publisher Wiley
record_format ai
recordtype ai
series Medical Physics
source_id 49
spelling Jang, Deok Hyun Da Silva, Eric Tavakkoli, Jahan Slatkovska, Lubomira Cheung, Angela M. Pejović‐Milić, Ana 0094-2405 2473-4209 Wiley General Medicine http://dx.doi.org/10.1002/mp.12641 <jats:sec><jats:title>Purpose</jats:title><jats:p>Dual‐energy X‐ray absorptiometry (DXA) is the gold standard technique to measure areal bone mineral density (aBMD) for the diagnosis of osteoporosis. Because DXA relies on the attenuation of photon to estimate aBMD, deposition of bone‐seeking metallic elements such as strontium, lead, and aluminum that differ in atomic numbers from calcium can cause inaccurate estimation of aBMD. Quantitative ultrasound (QUS) is another technique available to assess bone health by measuring broadband ultrasound attenuation (BUA), speed of sound (SOS), and an empirically derived quantity called stiffness index (SI). Because the acoustic properties are not prone to significant change due to changes in microscopic atomic composition of bone, it is hypothesized that QUS is unaffected by the presence of bone‐seeking elements in the bone. The objective of this study was to investigate the effect of strontium, lead, and aluminum on DXA‐derived aBMD and QUS parameters using bone‐mimicking phantoms compatible with both techniques.</jats:p></jats:sec><jats:sec><jats:title>Methods</jats:title><jats:p>Bone‐mimicking phantoms were produced by homogeneously mixing finely powdered hydroxyapatite compounds that contain varying concentrations of strontium, lead, or aluminum with porcine gelatin solution. Seven strontium‐substituted phantoms were produced with varying molar ratio of Sr/(Sr + Ca) ranging from 0% to 2%. Four lead‐doped phantoms and four aluminum‐doped phantoms were constructed with the respective analyte concentrations ranging from 50 to 200 ppm. An additional 0 ppm phantom was produced to be used as a baseline for the lead and aluminum phantom measurements. All phantoms had uniform volumetric bone mineral density (vBMD) of 200 mg/cm<jats:sup>3</jats:sup>, and were assessed using a Hologic Horizon<jats:sup>®</jats:sup> DXA device and a Hologic Sahara<jats:sup>®</jats:sup> QUS device. Furthermore, theoretical aBMD bias for mol/mol% substitution of calcium with the three bone‐seeking elements was calculated.</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Strong positive linear relationship was found between aBMD measured by DXA and strontium concentration (<jats:italic>P</jats:italic> &lt; 0.001, <jats:italic>r</jats:italic> = 0.995). From the measurement of lead and aluminum phantoms using DXA, no statistically significant relationship was observed between aBMD and the analyte concentrations. For the QUS system, with an exception of BUA and lead concentration that exhibited statistically significant relationship (<jats:italic>P</jats:italic> &lt; 0.038, <jats:italic>r</jats:italic> = 0.899), no statistically significant change was observed in all QUS parameters with respect to the clinically relevant concentration of all three elements. The calculated theoretical aBMD bias induced by 1 mol/mol% substitution of calcium with strontium, lead, and aluminum were 10.8%, 4.6%, and −0.7%, respectively.</jats:p></jats:sec><jats:sec><jats:title>Conclusion</jats:title><jats:p>aBMD measured by DXA was prone to overestimation in the presence of strontium, but acoustic parameters measured by QUS are independent of strontium concentration. The deviation in aBMD induced by the clinically relevant concentrations of lead and aluminum under 200 ppm could not be detected using the Hologic Horizon<jats:sup>®</jats:sup> DXA device. Furthermore, the SI measured by the QUS system was not affected by lead or aluminum concentrations used in this study.</jats:p></jats:sec> Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study Medical Physics
spellingShingle Jang, Deok Hyun, Da Silva, Eric, Tavakkoli, Jahan, Slatkovska, Lubomira, Cheung, Angela M., Pejović‐Milić, Ana, Medical Physics, Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study, General Medicine
title Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_full Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_fullStr Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_full_unstemmed Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_short Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
title_sort assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: a phantom study
title_unstemmed Assessment of the effect of strontium, lead, and aluminum in bone on dual‐energy x‐ray absorptiometry and quantitative ultrasound measurements: A phantom study
topic General Medicine
url http://dx.doi.org/10.1002/mp.12641