Eintrag weiter verarbeiten
Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode
Gespeichert in:
Zeitschriftentitel: | Electroanalysis |
---|---|
Personen und Körperschaften: | , , |
In: | Electroanalysis, 23, 2011, 3, S. 737-746 |
Format: | E-Article |
Sprache: | Englisch |
veröffentlicht: |
Wiley
|
Schlagwörter: |
author_facet |
Atta, Nada F. Galal, Ahmed Ahmed, Rasha A. Atta, Nada F. Galal, Ahmed Ahmed, Rasha A. |
---|---|
author |
Atta, Nada F. Galal, Ahmed Ahmed, Rasha A. |
spellingShingle |
Atta, Nada F. Galal, Ahmed Ahmed, Rasha A. Electroanalysis Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode Electrochemistry Analytical Chemistry |
author_sort |
atta, nada f. |
spelling |
Atta, Nada F. Galal, Ahmed Ahmed, Rasha A. 1040-0397 1521-4109 Wiley Electrochemistry Analytical Chemistry http://dx.doi.org/10.1002/elan.201000600 <jats:title>Abstract</jats:title><jats:p>A simple and rapid method for morphine detection is described based on PEDOT electrode in the presence of SDS. The electrochemistry of morphine is investigated by CV, LSV and SWV. The effect of common interferences on the current response of morphine namely AA and UA is studied. The electrode is applied to the selective determination of morphine in urine samples in the linear ranges 0.3–8 µmol L<jats:sup>−1</jats:sup> and 10–60 µmol L<jats:sup>−1</jats:sup>, with low detection limits of 50 and 68 nmol L<jats:sup>−1</jats:sup>, respectively and recovery of 96.4 %. The application of PEDOT is realized in determination of morphine in tablets successfully.</jats:p> Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode Electroanalysis |
doi_str_mv |
10.1002/elan.201000600 |
facet_avail |
Online |
finc_class_facet |
Technik Physik Chemie und Pharmazie |
format |
ElectronicArticle |
fullrecord |
blob:ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTAwMi9lbGFuLjIwMTAwMDYwMA |
id |
ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTAwMi9lbGFuLjIwMTAwMDYwMA |
institution |
DE-15 DE-Pl11 DE-Rs1 DE-105 DE-14 DE-Ch1 DE-L229 DE-D275 DE-Bn3 DE-Brt1 DE-D161 DE-Gla1 DE-Zi4 |
imprint |
Wiley, 2011 |
imprint_str_mv |
Wiley, 2011 |
issn |
1040-0397 1521-4109 |
issn_str_mv |
1040-0397 1521-4109 |
language |
English |
mega_collection |
Wiley (CrossRef) |
match_str |
atta2011directandsimpleelectrochemicaldeterminationofmorphineatpedotmodifiedptelectrode |
publishDateSort |
2011 |
publisher |
Wiley |
recordtype |
ai |
record_format |
ai |
series |
Electroanalysis |
source_id |
49 |
title |
Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_unstemmed |
Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_full |
Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_fullStr |
Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_full_unstemmed |
Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_short |
Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_sort |
direct and simple electrochemical determination of morphine at pedot modified pt electrode |
topic |
Electrochemistry Analytical Chemistry |
url |
http://dx.doi.org/10.1002/elan.201000600 |
publishDate |
2011 |
physical |
737-746 |
description |
<jats:title>Abstract</jats:title><jats:p>A simple and rapid method for morphine detection is described based on PEDOT electrode in the presence of SDS. The electrochemistry of morphine is investigated by CV, LSV and SWV. The effect of common interferences on the current response of morphine namely AA and UA is studied. The electrode is applied to the selective determination of morphine in urine samples in the linear ranges 0.3–8 µmol L<jats:sup>−1</jats:sup> and 10–60 µmol L<jats:sup>−1</jats:sup>, with low detection limits of 50 and 68 nmol L<jats:sup>−1</jats:sup>, respectively and recovery of 96.4 %. The application of PEDOT is realized in determination of morphine in tablets successfully.</jats:p> |
container_issue |
3 |
container_start_page |
737 |
container_title |
Electroanalysis |
container_volume |
23 |
format_de105 |
Article, E-Article |
format_de14 |
Article, E-Article |
format_de15 |
Article, E-Article |
format_de520 |
Article, E-Article |
format_de540 |
Article, E-Article |
format_dech1 |
Article, E-Article |
format_ded117 |
Article, E-Article |
format_degla1 |
E-Article |
format_del152 |
Buch |
format_del189 |
Article, E-Article |
format_dezi4 |
Article |
format_dezwi2 |
Article, E-Article |
format_finc |
Article, E-Article |
format_nrw |
Article, E-Article |
_version_ |
1792344880169615363 |
geogr_code |
not assigned |
last_indexed |
2024-03-01T17:14:38.216Z |
geogr_code_person |
not assigned |
openURL |
url_ver=Z39.88-2004&ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fvufind.svn.sourceforge.net%3Agenerator&rft.title=Direct+and+Simple+Electrochemical+Determination+of+Morphine+at+PEDOT+Modified+Pt+Electrode&rft.date=2011-03-01&genre=article&issn=1521-4109&volume=23&issue=3&spage=737&epage=746&pages=737-746&jtitle=Electroanalysis&atitle=Direct+and+Simple+Electrochemical+Determination+of+Morphine+at+PEDOT+Modified+Pt+Electrode&aulast=Ahmed&aufirst=Rasha+A.&rft_id=info%3Adoi%2F10.1002%2Felan.201000600&rft.language%5B0%5D=eng |
SOLR | |
_version_ | 1792344880169615363 |
author | Atta, Nada F., Galal, Ahmed, Ahmed, Rasha A. |
author_facet | Atta, Nada F., Galal, Ahmed, Ahmed, Rasha A., Atta, Nada F., Galal, Ahmed, Ahmed, Rasha A. |
author_sort | atta, nada f. |
container_issue | 3 |
container_start_page | 737 |
container_title | Electroanalysis |
container_volume | 23 |
description | <jats:title>Abstract</jats:title><jats:p>A simple and rapid method for morphine detection is described based on PEDOT electrode in the presence of SDS. The electrochemistry of morphine is investigated by CV, LSV and SWV. The effect of common interferences on the current response of morphine namely AA and UA is studied. The electrode is applied to the selective determination of morphine in urine samples in the linear ranges 0.3–8 µmol L<jats:sup>−1</jats:sup> and 10–60 µmol L<jats:sup>−1</jats:sup>, with low detection limits of 50 and 68 nmol L<jats:sup>−1</jats:sup>, respectively and recovery of 96.4 %. The application of PEDOT is realized in determination of morphine in tablets successfully.</jats:p> |
doi_str_mv | 10.1002/elan.201000600 |
facet_avail | Online |
finc_class_facet | Technik, Physik, Chemie und Pharmazie |
format | ElectronicArticle |
format_de105 | Article, E-Article |
format_de14 | Article, E-Article |
format_de15 | Article, E-Article |
format_de520 | Article, E-Article |
format_de540 | Article, E-Article |
format_dech1 | Article, E-Article |
format_ded117 | Article, E-Article |
format_degla1 | E-Article |
format_del152 | Buch |
format_del189 | Article, E-Article |
format_dezi4 | Article |
format_dezwi2 | Article, E-Article |
format_finc | Article, E-Article |
format_nrw | Article, E-Article |
geogr_code | not assigned |
geogr_code_person | not assigned |
id | ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTAwMi9lbGFuLjIwMTAwMDYwMA |
imprint | Wiley, 2011 |
imprint_str_mv | Wiley, 2011 |
institution | DE-15, DE-Pl11, DE-Rs1, DE-105, DE-14, DE-Ch1, DE-L229, DE-D275, DE-Bn3, DE-Brt1, DE-D161, DE-Gla1, DE-Zi4 |
issn | 1040-0397, 1521-4109 |
issn_str_mv | 1040-0397, 1521-4109 |
language | English |
last_indexed | 2024-03-01T17:14:38.216Z |
match_str | atta2011directandsimpleelectrochemicaldeterminationofmorphineatpedotmodifiedptelectrode |
mega_collection | Wiley (CrossRef) |
physical | 737-746 |
publishDate | 2011 |
publishDateSort | 2011 |
publisher | Wiley |
record_format | ai |
recordtype | ai |
series | Electroanalysis |
source_id | 49 |
spelling | Atta, Nada F. Galal, Ahmed Ahmed, Rasha A. 1040-0397 1521-4109 Wiley Electrochemistry Analytical Chemistry http://dx.doi.org/10.1002/elan.201000600 <jats:title>Abstract</jats:title><jats:p>A simple and rapid method for morphine detection is described based on PEDOT electrode in the presence of SDS. The electrochemistry of morphine is investigated by CV, LSV and SWV. The effect of common interferences on the current response of morphine namely AA and UA is studied. The electrode is applied to the selective determination of morphine in urine samples in the linear ranges 0.3–8 µmol L<jats:sup>−1</jats:sup> and 10–60 µmol L<jats:sup>−1</jats:sup>, with low detection limits of 50 and 68 nmol L<jats:sup>−1</jats:sup>, respectively and recovery of 96.4 %. The application of PEDOT is realized in determination of morphine in tablets successfully.</jats:p> Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode Electroanalysis |
spellingShingle | Atta, Nada F., Galal, Ahmed, Ahmed, Rasha A., Electroanalysis, Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode, Electrochemistry, Analytical Chemistry |
title | Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_full | Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_fullStr | Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_full_unstemmed | Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_short | Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
title_sort | direct and simple electrochemical determination of morphine at pedot modified pt electrode |
title_unstemmed | Direct and Simple Electrochemical Determination of Morphine at PEDOT Modified Pt Electrode |
topic | Electrochemistry, Analytical Chemistry |
url | http://dx.doi.org/10.1002/elan.201000600 |