author_facet Xue, Zhi‐Lun
Karagözler, A Ersin
Ataman, O. Yavuz
Galal, Ahmed
Amer, Adel
Shabana, R.
Zimmer, Hans
Mark, Harry B.
Xue, Zhi‐Lun
Karagözler, A Ersin
Ataman, O. Yavuz
Galal, Ahmed
Amer, Adel
Shabana, R.
Zimmer, Hans
Mark, Harry B.
author Xue, Zhi‐Lun
Karagözler, A Ersin
Ataman, O. Yavuz
Galal, Ahmed
Amer, Adel
Shabana, R.
Zimmer, Hans
Mark, Harry B.
spellingShingle Xue, Zhi‐Lun
Karagözler, A Ersin
Ataman, O. Yavuz
Galal, Ahmed
Amer, Adel
Shabana, R.
Zimmer, Hans
Mark, Harry B.
Electroanalysis
Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
Electrochemistry
Analytical Chemistry
author_sort xue, zhi‐lun
spelling Xue, Zhi‐Lun Karagözler, A Ersin Ataman, O. Yavuz Galal, Ahmed Amer, Adel Shabana, R. Zimmer, Hans Mark, Harry B. 1040-0397 1521-4109 Wiley Electrochemistry Analytical Chemistry http://dx.doi.org/10.1002/elan.1140020103 <jats:title>Abstract</jats:title><jats:p>A conducting, chemically synthesized, Cu(II)‐containing poly(3‐methylthiophene) powder was pressed into a pellet and used as the working electrode of a three‐electrode system in a thin‐layer amperometric cell unit to detect ionic analytes in an aqueous stream by flow‐injection analysis. The electrode response was linearly correlated with the applied voltage, which was varied between 0.2 and 3.0 V (vs. Ag/AgCI). It was shown that the electrode possesses favorable sensitivity and stability in comparison with other metallic electrodes such as stainless steel and Pt. During a period of more than a year, it showed no deterioration in its performance.</jats:p> Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode Electroanalysis
doi_str_mv 10.1002/elan.1140020103
facet_avail Online
finc_class_facet Technik
Physik
Chemie und Pharmazie
format ElectronicArticle
fullrecord blob:ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTAwMi9lbGFuLjExNDAwMjAxMDM
id ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTAwMi9lbGFuLjExNDAwMjAxMDM
institution DE-Pl11
DE-Rs1
DE-105
DE-14
DE-Ch1
DE-L229
DE-D275
DE-Bn3
DE-Brt1
DE-D161
DE-Gla1
DE-Zi4
DE-15
imprint Wiley, 1990
imprint_str_mv Wiley, 1990
issn 1040-0397
1521-4109
issn_str_mv 1040-0397
1521-4109
language English
mega_collection Wiley (CrossRef)
match_str xue1990conductivitymonitoringbyanamperometricdetectorwithacuiicontainingpoly3methylthiopheneelectrode
publishDateSort 1990
publisher Wiley
recordtype ai
record_format ai
series Electroanalysis
source_id 49
title Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_unstemmed Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_full Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_fullStr Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_full_unstemmed Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_short Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_sort conductivity monitoring by an amperometric detector with a cu(ii)‐containing poly(3‐methylthiophene) electrode
topic Electrochemistry
Analytical Chemistry
url http://dx.doi.org/10.1002/elan.1140020103
publishDate 1990
physical 1-7
description <jats:title>Abstract</jats:title><jats:p>A conducting, chemically synthesized, Cu(II)‐containing poly(3‐methylthiophene) powder was pressed into a pellet and used as the working electrode of a three‐electrode system in a thin‐layer amperometric cell unit to detect ionic analytes in an aqueous stream by flow‐injection analysis. The electrode response was linearly correlated with the applied voltage, which was varied between 0.2 and 3.0 V (vs. Ag/AgCI). It was shown that the electrode possesses favorable sensitivity and stability in comparison with other metallic electrodes such as stainless steel and Pt. During a period of more than a year, it showed no deterioration in its performance.</jats:p>
container_issue 1
container_start_page 1
container_title Electroanalysis
container_volume 2
format_de105 Article, E-Article
format_de14 Article, E-Article
format_de15 Article, E-Article
format_de520 Article, E-Article
format_de540 Article, E-Article
format_dech1 Article, E-Article
format_ded117 Article, E-Article
format_degla1 E-Article
format_del152 Buch
format_del189 Article, E-Article
format_dezi4 Article
format_dezwi2 Article, E-Article
format_finc Article, E-Article
format_nrw Article, E-Article
_version_ 1792336974356414477
geogr_code not assigned
last_indexed 2024-03-01T15:08:57.112Z
geogr_code_person not assigned
openURL url_ver=Z39.88-2004&ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fvufind.svn.sourceforge.net%3Agenerator&rft.title=Conductivity+monitoring+by+an+amperometric+detector+with+a+Cu%28II%29%E2%80%90containing+poly%283%E2%80%90methylthiophene%29+electrode&rft.date=1990-01-01&genre=article&issn=1521-4109&volume=2&issue=1&spage=1&epage=7&pages=1-7&jtitle=Electroanalysis&atitle=Conductivity+monitoring+by+an+amperometric+detector+with+a+Cu%28II%29%E2%80%90containing+poly%283%E2%80%90methylthiophene%29+electrode&aulast=Mark&aufirst=Harry+B.&rft_id=info%3Adoi%2F10.1002%2Felan.1140020103&rft.language%5B0%5D=eng
SOLR
_version_ 1792336974356414477
author Xue, Zhi‐Lun, Karagözler, A Ersin, Ataman, O. Yavuz, Galal, Ahmed, Amer, Adel, Shabana, R., Zimmer, Hans, Mark, Harry B.
author_facet Xue, Zhi‐Lun, Karagözler, A Ersin, Ataman, O. Yavuz, Galal, Ahmed, Amer, Adel, Shabana, R., Zimmer, Hans, Mark, Harry B., Xue, Zhi‐Lun, Karagözler, A Ersin, Ataman, O. Yavuz, Galal, Ahmed, Amer, Adel, Shabana, R., Zimmer, Hans, Mark, Harry B.
author_sort xue, zhi‐lun
container_issue 1
container_start_page 1
container_title Electroanalysis
container_volume 2
description <jats:title>Abstract</jats:title><jats:p>A conducting, chemically synthesized, Cu(II)‐containing poly(3‐methylthiophene) powder was pressed into a pellet and used as the working electrode of a three‐electrode system in a thin‐layer amperometric cell unit to detect ionic analytes in an aqueous stream by flow‐injection analysis. The electrode response was linearly correlated with the applied voltage, which was varied between 0.2 and 3.0 V (vs. Ag/AgCI). It was shown that the electrode possesses favorable sensitivity and stability in comparison with other metallic electrodes such as stainless steel and Pt. During a period of more than a year, it showed no deterioration in its performance.</jats:p>
doi_str_mv 10.1002/elan.1140020103
facet_avail Online
finc_class_facet Technik, Physik, Chemie und Pharmazie
format ElectronicArticle
format_de105 Article, E-Article
format_de14 Article, E-Article
format_de15 Article, E-Article
format_de520 Article, E-Article
format_de540 Article, E-Article
format_dech1 Article, E-Article
format_ded117 Article, E-Article
format_degla1 E-Article
format_del152 Buch
format_del189 Article, E-Article
format_dezi4 Article
format_dezwi2 Article, E-Article
format_finc Article, E-Article
format_nrw Article, E-Article
geogr_code not assigned
geogr_code_person not assigned
id ai-49-aHR0cDovL2R4LmRvaS5vcmcvMTAuMTAwMi9lbGFuLjExNDAwMjAxMDM
imprint Wiley, 1990
imprint_str_mv Wiley, 1990
institution DE-Pl11, DE-Rs1, DE-105, DE-14, DE-Ch1, DE-L229, DE-D275, DE-Bn3, DE-Brt1, DE-D161, DE-Gla1, DE-Zi4, DE-15
issn 1040-0397, 1521-4109
issn_str_mv 1040-0397, 1521-4109
language English
last_indexed 2024-03-01T15:08:57.112Z
match_str xue1990conductivitymonitoringbyanamperometricdetectorwithacuiicontainingpoly3methylthiopheneelectrode
mega_collection Wiley (CrossRef)
physical 1-7
publishDate 1990
publishDateSort 1990
publisher Wiley
record_format ai
recordtype ai
series Electroanalysis
source_id 49
spelling Xue, Zhi‐Lun Karagözler, A Ersin Ataman, O. Yavuz Galal, Ahmed Amer, Adel Shabana, R. Zimmer, Hans Mark, Harry B. 1040-0397 1521-4109 Wiley Electrochemistry Analytical Chemistry http://dx.doi.org/10.1002/elan.1140020103 <jats:title>Abstract</jats:title><jats:p>A conducting, chemically synthesized, Cu(II)‐containing poly(3‐methylthiophene) powder was pressed into a pellet and used as the working electrode of a three‐electrode system in a thin‐layer amperometric cell unit to detect ionic analytes in an aqueous stream by flow‐injection analysis. The electrode response was linearly correlated with the applied voltage, which was varied between 0.2 and 3.0 V (vs. Ag/AgCI). It was shown that the electrode possesses favorable sensitivity and stability in comparison with other metallic electrodes such as stainless steel and Pt. During a period of more than a year, it showed no deterioration in its performance.</jats:p> Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode Electroanalysis
spellingShingle Xue, Zhi‐Lun, Karagözler, A Ersin, Ataman, O. Yavuz, Galal, Ahmed, Amer, Adel, Shabana, R., Zimmer, Hans, Mark, Harry B., Electroanalysis, Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode, Electrochemistry, Analytical Chemistry
title Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_full Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_fullStr Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_full_unstemmed Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_short Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
title_sort conductivity monitoring by an amperometric detector with a cu(ii)‐containing poly(3‐methylthiophene) electrode
title_unstemmed Conductivity monitoring by an amperometric detector with a Cu(II)‐containing poly(3‐methylthiophene) electrode
topic Electrochemistry, Analytical Chemistry
url http://dx.doi.org/10.1002/elan.1140020103